Description Planar Lightwave Circuit (PLC) Splitter is a type of optical power management device that is fabricated using silica optical waveguide technology. It features small size, high reliability, wide operating wavelength range and good channel-to-channel uniformity, and is widely used in PON networks to realize optical signal power splitting. Fiberwell provides whole series of 1xN splitter and 2xN splitter products that are tailored for specific applications. All products meet GR-1209-CORE-2001 and GR-1221-CORE-1999 requirements.
Features
1) Low Insertion loss
2) Low PDL
3) Compact Design
4) Good channel-to-channel uniformity
5) Wide Operating Wavelength: From 1260nm to 1650nm
6) Wide Operating Temperature: From -40℃ to 85℃
7) High Reliability and Stability
Applications
1) Can be used for FTTX Systems
2) Passive Optical Networks (PON)
3) CATV TV Networks (CATV)
4) Optical Signal Distribution
Compliance
1) Telcordia GR-1209-CORE-2001
2) Telcordia GR-1221-CORE-1999
3) YD/T1117-2001
1xN PLC Splitter Specifications
Port Configuration |
1x2 |
1x4 |
1x8 |
1x16 |
1x32 |
1x64 |
Fiber Type |
SMF28-e or customer specified |
Operating Wavelength (nm) |
1260~1650 |
Insertion Loss (dB) |
Typical |
3.7 |
6.8 |
10.0 |
13.0 |
16.0 |
19.5 |
Max |
4.0 |
7.2 |
10.5 |
13.5 |
16.9 |
21.0 |
Loss Uniformity(dB) |
Max |
0.4 |
0.6 |
0.8 |
1.2 |
1.5 |
2.5 |
Return Loss (dB) |
Min |
50 |
50 |
50 |
50 |
50 |
50 |
Polarization Dependent Loss(dB) |
Max |
0.2 |
0.2 |
0.3 |
0.3 |
0.3 |
0.4 |
Directivity (dB) |
Min |
55 |
55 |
55 |
55 |
55 |
55 |
Wavelength Dependent Loss(dB) |
Max |
0.3 |
0.3 |
0.3 |
0.5 |
0.5 |
0.8 |
Temperature Stability (-40~85 ℃)(dB) |
Max |
0.5 |
0.5 |
0.5 |
0.8 |
0.8 |
1.0 |
Operating Temperature (℃) |
|
-40~85 |
Storage Temperature (℃) |
|
-40~85 |
Package Size (mm) |
|
40x4x4 |
50x4x4 |
50x7x4 |
60x12x4 |
Note: All the data above does not include connectors.
Add an additional 0.2dB loss per connector.
2xN PLC Splitter Specifications
Port Configuration |
2x2 |
2x4 |
2x8 |
2x16 |
2x32 |
2x64 |
Fiber Type |
SMF28-e or customer specified |
Operating Wavelength (nm) |
1260~1650 |
Insertion Loss (dB) |
Typical |
3.8 |
7.4 |
10.8 |
14.2 |
17.0 |
21.0 |
Max |
4.2 |
7.8 |
11.2 |
14.6 |
17.5 |
21.5 |
Loss Uniformity(dB) |
Max |
1.0 |
1.4 |
1.5 |
2.0 |
2.5 |
2.5 |
Return Loss (dB) |
Min |
50 |
50 |
50 |
50 |
50 |
50 |
Polarization Dependent Loss(dB) |
Max |
0.2 |
0.2 |
0.4 |
0.4 |
0.4 |
0.5 |
Directivity (dB) |
Min |
55 |
55 |
55, |
55 |
55 |
55 |
Wavelength Dependent Loss(dB) |
Max |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
1.0 |
Temperature Stability (-40~85 ℃)(dB) |
Max |
0.5 |
0.5 |
0.5 |
0.8 |
0.8 |
1.0 |
Operating Temperature (℃) |
|
-40~85 |
Storage Temperature (℃) |
|
-40~85 |
Package Size (mm) |
|
40x4x4 |
50x7x4 |
60x7x4 |
60x12x4 |
Note: All the data above does not include connectors.
Add an additional 0.2dB loss per connector.
Ordering Information
Type |
Package size |
Port |
Fiber Type |
Input/output pigtail<, SPAN, styl, e="mso-bookmark: OLE_LINK2"> |
Fiber length |
In/out connector |
PLCS |
BF=bare fiber
FO=fan-out
ST= steel tube
AB=ABS box
MB=metal box |
01X02
01x04
01x08
……
02x16
02x32
02x64 |
0=G652D
1=G657A
C=Customize |
1=bare fiber
2=900µm
tight buffered
3=2.0mm
Loose tube
4=3.0mm
Loose tube
5=2.0mm cable
6=3.0mm cable |
1=1m
2=1.5m
C=Customize |
0=no connector
1=FC/APC
2=FC/PC
3=SC/APC
4=SC/PC
5=ST/APC
6=ST/PC
7=LC/AP
8=LC/PC
C=customize |
·
|